HDX
COMMERCIAL
SERIES
Stop fouling, cut costs, and save time, all while boosting efficiency and performance.
Hull Shield HDX systems provide comprehensive protection for hulls, props, shafts, jet-drives, pods, steerage, control gear, sea chests, box coolers, pipework, keel coolers, heat exchangers, RSW cooling systems, and bulk storage tanks. Marine operators using Hull Shield HDX systems benefit from reduced fuel consumption, lower emissions, improved performance, more responsive and safer handling, extended service intervals, and increased asset lifespan.
HDX antifouling products operate continuously, 24/7, to target and prevent biofouling on surfaces that require protection.
Hull Shield’s HDX Series meets the demand for more powerful and robust ultrasonic antifouling solutions that can protect valuable marine assets from biofouling. Our HDX systems provide the highest unit transfer of ultrasound power in the industry, delivering greater range and penetration when compared to anything else available.
- HALTS FOULING
- MITIGATES RISK
- REDUCES DAMAGE
- INCREASES EFFICIENC
- BOOSTS PERFORMANCE
PROTECTING YOUR ASSETS
Hulls
Hulls can be fitted with a distributed array of ultrasonic transducers. Hull Shield transducers will function together to provide complete coverage of the submerged structure.
Shafts & Props
Bio-fouling accumulation on shafts and props can be detrimental to fuel efficiency. Hull Shield can deliver ultrasound directly into the prop via the shaft, adding protection to both simultaneously.
Pod-Drives
When pods become fouled, both thrust and steerage are affected. Fouling leads to poor fuel efficiency and reduced handling response. Z-Drive and L-Drive pods can be targeted directly with Hull Shield ultrasonic antifouling.
Jet-Drives
Performance and efficiency can suffer significantly from fouling inside the drive. Fouling remediation can be complicated and increase downtime. Hull Shield can target jet-drives to reduce fouling and maintenance.
Steering & Control Gear
Hull Shield ultrasound can be used to target steering, stabilizing, and other control surfaces. Reducing fouling on these surfaces increases hydrodynamic efficiency and results in more responsive and safer handling of the vessel.
Sea Chests & Box Coolers
Invasive biofouling in sea chests and box coolers reduces cooling capacity and increases maintenance downtime. If left uncheck, fouling within the cooling system can lead to equipment failure. Ultrasonic antifouling can be easily deployed to protect these areas using non-intrusive installation methods.
Pipework & Valves
Biofouling can affect the flow rate and function of various types of pipework. Targeted ultrasound treatment is effective at reducing fouling in pipes and decreasing subsequent maintenance intervals and downtime.
Keel Coolers
Keel coolers have constant exposure to raw seawater. Bio-fouling accumulation on the cooling elements leads to reduced cooling capacity and downtime. Hull Shield ultrasonic transducers can specifically target these exterior components.
Heat Exchangers & RSW Cooling
All inboard open circuit systems are prone to damage caused by fouling accumulation and require routine maintenance. Ultrasound can be deployed to mitigate biofouling and increase system efficiency.
Diesel & Water Tank Storage
Diesel fuel and water storage tanks are susceptible to the dangerous and damaging effects of fouling and bacteria. Ultrasound is effective at mitigating the consequences of bacteria and microbe accumulation in these reservoirs.
HDX Series Technical Details
OPERATING CHARACTERISTICS
Maximum Input Voltage
Operating Voltage Range
Output Voltage Range (VAC)
Operating Temperature
36.0V
24.0V to 28.0V
230V to 280V (RMS)
-22F to 140F (-30C to 60C)
FREQUENCY & PULSE
Frequency Range
MAX Sustained Pulse Power
Peak Pulse Power (<1ms)
22,727 Hz to 41,666 Hz
72 Watts
90 Watts
RATINGS
Enclosure
Signal Connectors
Rocker Switch
Power/Auxiliary Cable
IP68, NEMA 6P,12; UL94 V-0; UL746C 5VA
IP67; IP68; UL94 V-0
IP67, RoHS-3
UL2464; VW-1; 80C; RoHS
HDX Series Technical Details
OPERATING CHARACTERISTICS
Maximum Input Voltage
Operating Voltage Range
Output Voltage Range (VAC)
Operating Temperature
36.0V
24.0V to 28.0V
230V to 280V (RMS)
-22F to 140F (-30C to 60C)
FREQUENCY & PULSE
Frequency Range
MAX Sustained Pulse Power
Peak Pulse Power (<1ms)
22,727 Hz to 41,666 Hz
72 Watts
90 Watts
RATINGS
Enclosure
Signal Connectors
Rocker Switch
Power/Auxiliary Cable
IP68, NEMA 6P,12; UL94 V-0; UL746C 5VA
IP67; IP68; UL94 V-0
IP67, RoHS-3
UL2464; VW-1; 80C; RoHS