Customer Service
+1 888 812 6287


Couldn't load pickup availability
Fireboy-Xintex G-2BB-R, Mariners Warehouse SKU 63872, is a 2-channel gasoline-fume detection package with a black square display and two fuel-fume sensors and two 20-foot extension cables. Its blower-control arrangement can actuate a correctly connected bilge-blower system under the exact instructions. Choose it by the number of sensing locations, actual supply and required control function.
The display provides audible alarm and visual operational, fault and alarm indications for the supported sensor channels. The exact blower-control manufacturer manual specifies a 9–30V DC detector supply, 95mA nominal at 12V and 150mA maximum at 9V. The blower interface is a maximum 2A control output; use the specified external relay arrangement rather than applying that output directly to an arbitrary motor. This is supplemental gasoline-fume warning equipment, not a carbon-monoxide alarm or a substitute for proper fuel-system maintenance and ventilation.
Have a qualified installer confirm the exact display, sensor and cable versions before cutting or wiring. Use the prescribed panel cutout, sensor locations, routing and protected power connection. The listed 12V blower-kit application and exact supplied relay must be matched to the actual blower circuit even though the detector electronics accept 9–30V DC. Test the display and sensors using the separate manufacturer procedures, retain the maintenance schedule and follow the full alarm-response instructions. Never treat a quiet or muted alarm as permission to ignore a suspected fuel leak.
Review one detector kit with 2 sensors and the confirmed configuration before ordering. Check the shipping options and delivery estimate shown for your destination at checkout.
Have a qualified installer confirm the exact display, sensor and cable versions before cutting or wiring. Use the prescribed panel cutout, sensor locations, routing and protected power connection. The listed 12V blower-kit application and exact supplied relay must be matched to the actual blower circuit even though the detector electronics accept 9–30V DC. Test the display and sensors using the separate manufacturer procedures, retain the maintenance schedule and follow the full alarm-response instructions. Never treat a quiet or muted alarm as permission to ignore a suspected fuel leak. Inspect the delivered parts before starting the work.
Read the shipping policy or contact Mariners Warehouse with product and destination questions.
Review the 16 oz gel format, specifications and application directions.
Check fiberglass, gelcoat and finish suitability before use.
Ask about your surface and stain type before ordering.
Review shipping information and return conditions before purchase.
Compatibility & Setup Guides
Check G-2BB-R by its actual communication, heading, alarm-output, mounting or satellite-TV role. Confirm supported systems, power, connections, contents and setup requirements before purchasing.
G-2BB-R monitors gasoline fumes at 2 sensing points. It does not replace an RV CO/propane combination alarm or smoke alarm.
Confirm G-2BB-R, black bezel, channel count and blower-control function.
The detector electronics list 9–30V DC. Confirm the supplied relay, control output and actual blower circuit separately; a wide detector range does not approve every relay voltage.
Route the 2 supplied 20-foot cables to manufacturer-approved sensing positions. Keep the display visible and do not infer whole-compartment coverage from cable length.
One Fireboy-Xintex G-2BB-R detector/display, two fuel-fume sensors and two 20-foot extension cables, one listed blower relay, and instruction manual. The actual bilge blower, circuit wiring and protection are separate; match the supplied relay to the blower circuit.
Use the prescribed display and sensor tests, maintenance and alarm-response procedure. Detection remains supplemental to sound fuel-system practices.
G-2BB-R supplies dual-channel monitoring with blower control and a listed relay. G-2B-R supplies dual-channel monitoring without the blower-control package. Both exact listings include two sensors and two 20-foot extension cables for separately located sensing points.
Select by the required warning and blower-control functions, then compare the actual load circuit, relay marking, sensor routes and display space. Two channels describe two sensing points; they do not guarantee that gas in every compartment will reach a sensor. Review the Fireboy-Xintex Gasoline Fume Detector with Dual Channel - 12/24V MPN - G-2B-R as a separately sold option.
Choose by the actual communication, navigation, alarm or satellite-TV task, then compare exact compatibility and contents.
Compare radios, compasses, alarm accessories and satellite-TV equipment by their exact system role and requirements.
Review GPS cables and mounting accessories for a separate navigation task. Check every item’s exact model and interface; no compatible pairing is implied.
Return to the parent collection for another maintenance or replacement task. Check every item’s own requirements.
Need Help?
Need help comparing Fireboy-Xintex G-2BB-R 2-Channel Gasoline Fume Detector — Black with Blower Control, SKU 63872, MPN G-2BB-R? Share your exact detector version, required sensing locations, panel opening, sensor-cable routes, DC supply and blower/relay circuit details. These details help us understand your selection question before you order.
Trusted by 50,000+ boat owners across the USA
Our team has years of experience in marine parts.
We respond quickly to get you the help you need.
We make sure you get the right part the first time.
Access to 50,000+ marine parts & accessories.
Thanks for subscribing!
This email has been registered!