Fireboy-Xintex G-1BB-R, Mariners Warehouse SKU 63865, is a 1-channel gasoline-fume detection package with a black round display and one fuel-fume sensor and one 20-foot extension cable. Its blower-control arrangement can actuate a correctly connected bilge-blower system under the exact instructions. Choose it by the number of sensing locations, actual supply and required control function.

The display provides audible alarm and visual operational, fault and alarm indications for the supported sensor channels. The exact blower-control manufacturer manual specifies a 9–30V DC detector supply, 55mA nominal at 12V and 95mA maximum at 9V. The blower interface is a maximum 2A control output; use the specified external relay arrangement rather than applying that output directly to an arbitrary motor. This is supplemental gasoline-fume warning equipment, not a carbon-monoxide alarm or a substitute for proper fuel-system maintenance and ventilation.

Have a qualified installer confirm the exact display, sensor and cable versions before cutting or wiring. Use the prescribed panel cutout, sensor locations, routing and protected power connection. The listed 12V blower-kit application and exact supplied relay must be matched to the actual blower circuit even though the detector electronics accept 9–30V DC. Test the display and sensors using the separate manufacturer procedures, retain the maintenance schedule and follow the full alarm-response instructions. Never treat a quiet or muted alarm as permission to ignore a suspected fuel leak.

Clear Product Details

Review the 16 oz gel format, specifications and application directions.

Surface Guidance

Check fiberglass, gelcoat and finish suitability before use.

Product Support

Ask about your surface and stain type before ordering.

Shipping & Returns

Review shipping information and return conditions before purchase.

Compatibility & Setup Guides

Match the Device to Its Communication or Monitoring Task

Check G-1BB-R by its actual communication, heading, alarm-output, mounting or satellite-TV role. Confirm supported systems, power, connections, contents and setup requirements before purchasing.

Single-Channel Detector with or without Blower Control?

G-1BB-R is the black-bezel single-channel package with blower control and a listed relay. The separate G-1B-R package has the same one-area monitoring role but does not list the blower-control arrangement. Both need correct sensor placement and a supported power connection.

Choose the blower-control version only when the actual blower circuit and supplied relay match the approved installation. The detector’s wide input range does not establish the voltage or permitted motor load of every relay. If only warning/monitoring is needed, compare the no-blower package separately. Review the Fireboy-Xintex Gasoline Fume Detector - Black Bezel - 12/24V MPN - G-1B-R as a separately sold option.

Continue Your Communication & Monitoring Selection

Choose by the actual communication, navigation, alarm or satellite-TV task, then compare exact compatibility and contents.

Related Products

Frequently Asked Questions

What does SKU 63865 include?
One Fireboy-Xintex G-1BB-R detector/display, one fuel-fume sensor and one 20-foot extension cable, one listed blower relay, and instruction manual. The actual bilge blower, circuit wiring and protection are separate; match the supplied relay to the blower circuit.
How many sensors and cables are supplied?
1 sensor with one 20-foot cable.
Does this version include blower control?
Yes, a blower-control function and one relay are listed. Match the exact relay and load circuit; a blower motor is separate.
What supply does the detector require?
The exact manufacturer manual lists 9–30V DC for the detector electronics. Any relay and blower circuit must meet their own requirements.
What panel cutout should I check?
2-1/16-inch round hole for the single-channel display.
Is this a carbon-monoxide or smoke alarm?
No such detection is represented. Select it for its documented gasoline-fume warning role.
Does a quiet alarm prove there is no leak?
No. Follow normal fuel-system practices, maintenance and the exact response procedure whenever a leak is suspected; warnings depend on the installed and functioning sensor system.
How can I confirm the right selection?
Contact Mariners Warehouse with SKU 63865, MPN G-1BB-R, your exact detector version, required sensing locations, panel opening, sensor-cable routes, DC supply and blower/relay circuit details.

Recently Viewed Products

Need Help?

 Need Help Choosing the Right Marine Cleaning Product? 

Need help comparing Fireboy-Xintex G-1BB-R 1-Channel Gasoline Fume Detector — Black with Blower Control, SKU 63865, MPN G-1BB-R? Share your exact detector version, required sensing locations, panel opening, sensor-cable routes, DC supply and blower/relay circuit details. These details help us understand your selection question before you order.

Trusted by 50,000+ boat owners across the USA

A man wearing a navy blue polo shirt with a circular logo sits at a desk holding a metal engine component, with a laptop in front of him and a boat propeller on the table. A dark blue informational overlay on the right lists benefits like 'Talk to an Expert' and 'Find the Right Part'.
  • Expert Marine Support

    Our team has years of experience in marine parts.

  • Fast Response

    We respond quickly to get you the help you need.

  • Find Compatible Parts

    We make sure you get the right part the first time.

  • Huge Selection

    Access to 50,000+ marine parts & accessories.

Have a Part Number or Engine Model?

Send it to us and our experts will help you find the exact part you need.